banner



How To Repair A Broken High Tensile Fence

DSC_0624

Repairing your high-tensile electrical fence can be complicated. Luckily, Kencove is hither to help. With a few tools and supplies, your debate will be ready for bound calves, grazing sheep, or happy horses. Ideally, you want to read 6,000 to eight,000 volts or more on your fence. In our previous blog we detailed a quick listing of products yous will need to make major or pocket-size debate repairs. Yous likewise need to identify the parts of your fence that are in need of a tune up. Some popular repairs are cracked insulators, sagging wire, broken wire, and a loss of voltage. In one case you make your repairs, your voltage should come up dorsum. If non, we will walk you through some quick troubleshooting to identify where you are losing your voltage.

The first step is to check your insulators. Repairing a cracked or broken insulator can exist fourth dimension consuming and daunting. However, with Kencove's ingenious Spiralator insulator, you lot tin can quickly simplify this process. Check out this video on how to install a Spiralator.

Once you have replaced whatever croaky or missing insulators, check your fence voltage once again to see if you lot have addressed all the faults forth your argue. If you have non reached your desired voltage, and doubtable some other error forth your contend, bank check your connections.

Get-go by checking anywhere y'all have a crimp. Cheque for rust or other signs of weak wire such every bit scratched galvanization or bent wire. If you see an area of rusty or damaged wire, remove that department of wire and supersede it with new wire of the aforementioned gauge. You lot tin can accomplish this with a few crimps and a crimp tool. Depending on the guess of wire you are using, you lot will demand to select the proper crimp sleeves. Use ii-iii sleeves per splice, or one long sleeve.

DSC_0032

After repairing your damaged wire, examination your debate again. If y'all are withal experiencing a loss of voltage, it'south time to cheque your underground wire and electrical connections.

Typical clandestine wires go damaged rather chop-chop if they are left unprotected in heavy-traffic areas. The best way to install underground wire in these areas is by using some type of conduit. You will want to avoid water laying in this conduit, and then seal it upward every bit best you can.

Test your voltage on either side of all underground wires. If y'all see a drop in voltage on either side of your gate, information technology'southward rubber to say you need to replace this portion of your electrical organization. You will need new underground wire and a few split bolts or open tap crimps to fix this common event. Beginning by removing the current underground wire. If possible, effort calculation some type of pipe or conduit to protect and prolong the life of your new underground wire. Cut your new piece of hole-and-corner wire and use separate bolts to connect the energy back to either side of the gate, or use a simple open tap crimp sleeve to complete the energy circuit.

Test your fence over again to see if y'all have corrected all your faults. If y'all are still reading a low voltage, try testing your basis bed.

Yous want to read nether 2,000 volts on your ground rods. Starting time by turning your energizer off. Adjacent, simply "brusk out" your argue past leaning a metallic rod or mail service against your fence. Turn your analeptic dorsum on, and test your footing bed by testing the terminal rod in your serial of ground rods. If you are reading over 2,000 volts, continue calculation additional footing rods ten feet autonomously until you drop below 2,000 volts. Remember:

  • There is no such affair as too many ground rods
  • Basis rods demand to be at least x feet autonomously
  • Ground rods can exist anywhere along your debate line. They don't demand to be correct next to your energizer.
  • Ground beds need to exist at least 50 feet away from existing footing beds, underground wires, other pipes, and utility lines.

If you still aren't getting your desired voltage of half-dozen,000-8,000+ volts on your fence…well, you tried…better build a new fence! Just kidding, at that place are yet more places to check.

Try checking your brace wires to see if your hot wires are coming into contact with your not-insulated brace wire. If they are, you can use something simple like an old garden hose or a ringlet of Kencove's Spiralator to insulate these wires. You will want to insulate whatsoever wire that is touching or close to touching your hot wires. With the contact of these hot to non-insulated wires, you are sending your voltage straight to the ground, grounding out your debate organization.

You lot should likewise check your gates. If you are using spring or bungy gates, brand sure your gate handle isn't cracked or broken. This volition prevent unwanted zaps, and help improve the voltage forth your fence line. If your gate handle is cracked, it may be transferring voltage to your post, creating a curt in your contend. You may also need to replace your springs or bungy if they are over-stretched or twisted beyond repair.

Another mutual issue is caused from over sizing your energizer. If you have an extremely big energizer (high output joules) and a short debate, you are setting yourself up for induction. Induction is "the process past which an electrical conductor becomes electrified when near a charged trunk, by which a magnetizable body becomes magnetized when in a magnetic field or in the magnetic flux prepare by a magnetomotive strength, or by which an electromotive forcefulness is produced in a excursion by varying the magnetic field linked with the circuit.[1]"

In fence terms, consecration is when free energy jumps from your intended hot wires to things y'all practice not want hot, such as gates or not-insulated wires.

You can overcome induction by adding additional ground rods, checking to see if your energizer has a half ability setting, or insulating areas where the actress free energy is traveling such equally gates or not-insulated wires.

If y'all are still not getting the platonic voltage, you may have as well minor of an energizer. We recommend one output joule per mile of debate (regardless of the number of strands). If your analeptic gives yous a "miles or acres" rating and not an output-joule rating, try checking your transmission to observe its true output-joule rating. If your energizer is undersized, you may see a driblet in voltage downwardly your fence line, even though your energizer is reading high at the outset of your fence. For help on finding a properly sized energizer, bank check out our blog Bigger Isn't Always Better, or requite our product specialists a phone call at 1-800-KENCOVE.

DSC_0011

Other steps to have in preparing your high-tensile electrical debate include checking the tension on your wires. If y'all notice wires are sagging, you will need to tighten them using either a Gripple tensioner or a strainer. One of these tensioners should be installed on your fence. To add together more than tension, simply use either a Gripple Torque Tool for Gripples or a handle for your strainer. Once you have added tension to your fence, bank check your staples to ensure they are not as well tight or as well loose. Also double-check that your insulators are properly installed and protecting your hot wires.

You should also check to make certain your electric contend signs are legible. Depending on your state and local laws, sign requirements will vary. For the safety of others, and your ain protection, make sure warning signs are visible in loftier-traffic areas.

Terminal merely non least, don't forget to keep records of all repairs! This volition assistance you in isolating hereafter problem areas, besides every bit provide yous with a list of products you accept used. Keeping a small notebook near your analeptic is helpful in recording your typical debate voltage in diverse places, which makes testing a breeze the next time y'all are trying to identify your mistake.

If you need any help repairing your contend or finding the fault in your contend, give us a call at 1-800-KENCOVE. We are eager to aid with fence repairs, and we'd rather aid you now than when your cows are already eating your neighbor's prized roses. But don't worry, we'll still assistance y'all and so too!